Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1007/s00216-007-1754-5 |
Analysis of cocaine and its principal metabolites in waste and surface water using solid-phase extraction and liquid chromatography-ion trap tandem mass spectrometry | |
Gheorghe, Adriana2,3; van Nuijs, Alexander2; Pecceu, Bert4; Bervoets, Lieven4; Jorens, Philippe G.5; Blust, Ronny4; Neels, Hugo2; Covaci, Adrian1,2,4 | |
通讯作者 | Covaci, Adrian |
来源期刊 | ANALYTICAL AND BIOANALYTICAL CHEMISTRY
![]() |
ISSN | 1618-2642 |
出版年 | 2008 |
卷号 | 391期号:4页码:1309-1319 |
英文摘要 | A validated method based on solid-phase extraction (SPE) and liquid chromatography-ion trap tandem mass spectrometry (LC-MS/MS) is described for the determination of cocaine (COC) and its principal metabolites, benzoylecgonine (BE) and ecgonine methyl ester (EME), in waste and surface water. Several SPE adsorbents were investigated and the highest recoveries (95.7 +/- 5.5, 91.8 +/- 2.2 and 72.5 +/- 5.3% for COC, BE and EME, respectively) were obtained for OASIS HLB (R) cartridges (6 mL/500 mg) using 100 mL of waste water or 500 mL of surface water. Extracts were analysed by reversed-phase (RP) or hydrophilic interaction (HILIC) LC-MS/MS in positive ion mode with multiple reactions monitoring (MRM); the latter is the first reported application of the HILIC technique for drugs of abuse in water samples. Corresponding deuterated internal standards were used for quantification. The method limits of quantification (LOQs) for COC and BE were 4 and 2 ng L(-1), respectively, when RPLC was used and 1, 0.5 and 20 ng L(-1) for COC, BE and EME, respectively, with the HILIC setup. For COC and BE, the LOQs were below the concentrations measured in real water samples. Stability tests were conducted to establish the optimal conditions for sample storage (pH, temperature and time). The degradation of COC was minimal at -20 degrees C and pH = 2, but it was substantial at +20 degrees C and pH 6. The validated method was applied to a set of waste and surface water samples collected in Belgium. |
英文关键词 | cocaine metabolites LC-MS/MS waste water analytical method validation HILIC |
类型 | Article ; Proceedings Paper |
语种 | 英语 |
国家 | Belgium ; Romania |
收录类别 | SCI-E ; CPCI-S |
WOS记录号 | WOS:000256088700026 |
WOS关键词 | HYDROPHILIC INTERACTION CHROMATOGRAPHY ; ILLICIT DRUGS ; WHOLE-BLOOD ; PHARMACEUTICAL RESIDUES ; QUANTITATIVE-ANALYSIS ; HUMAN URINE ; IN-VITRO ; LC-MS/MS ; ABUSE ; PERFORMANCE |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/156381 |
作者单位 | 1.Univ Antwerp, Toxicol Ctr, B-2610 Antwerp, Belgium; 2.Univ Antwerp, Toxicol Ctr, B-2610 Antwerp, Belgium; 3.Univ Bucharest, Dept Analyt Chem, Bucharest 030018, Romania; 4.Univ Antwerp, Dept Biol, Lab Ecophysiol Biochem & Toxicol, B-2020 Antwerp, Belgium; 5.Univ Antwerp, Univ Antwerp Hosp, Dept Clin Pharmacol Clin Toxical, B-2610 Antwerp, Belgium |
推荐引用方式 GB/T 7714 | Gheorghe, Adriana,van Nuijs, Alexander,Pecceu, Bert,et al. Analysis of cocaine and its principal metabolites in waste and surface water using solid-phase extraction and liquid chromatography-ion trap tandem mass spectrometry[J],2008,391(4):1309-1319. |
APA | Gheorghe, Adriana.,van Nuijs, Alexander.,Pecceu, Bert.,Bervoets, Lieven.,Jorens, Philippe G..,...&Covaci, Adrian.(2008).Analysis of cocaine and its principal metabolites in waste and surface water using solid-phase extraction and liquid chromatography-ion trap tandem mass spectrometry.ANALYTICAL AND BIOANALYTICAL CHEMISTRY,391(4),1309-1319. |
MLA | Gheorghe, Adriana,et al."Analysis of cocaine and its principal metabolites in waste and surface water using solid-phase extraction and liquid chromatography-ion trap tandem mass spectrometry".ANALYTICAL AND BIOANALYTICAL CHEMISTRY 391.4(2008):1309-1319. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。