Arid
Effects of ventilation rate on the environment of a fan-pad evaporatively cooled, shaded greenhouse in extreme arid climates
Al-Helal, I. A.
通讯作者Al-Helal, I. A.
来源期刊APPLIED ENGINEERING IN AGRICULTURE
ISSN0883-8542
EISSN1943-7838
出版年2007
卷号23期号:2页码:221-230
英文摘要

A study was conducted to examine the influence of two ventilation rates on the environment of a shaded greenhouse equipped with fan-pad evaporative cooler during typical summer days in extreme and conditions. Temperature, relative humidity, and amounts of water and electrical energy consumed for cooling were investigated in a 39- X 9-m Quonset shaded greenhouse planted with cucumbers. Cooling was provided via an evaporative pad and two exhaust fans, each had a manufacturer’s ventilation rating of 10 m(3)/s [two fans provided 1 air exchange per minute (ACM) and one fan provided 0.5 ACM]. One fan was used from 0700 to 2000 h every other day, and two fans were used for the same period on the alternate days. Averages of daytime air temperature and relative humidity inside the greenhouse with a ventilation rate of 0.5 ACM were 33.6 degrees C and 33.50%, respectively, as compared to 30.2 degrees C and 37.5%, respectively, with a ventilation rate of 1 ACM, while the averages of outside temperature and relative humidity were 38.7 degrees C and 11%, respectively. Due to the greenhouse length, temperature gradients along the direction of the airflow were observed. The highest temperatures differences occurred between locations 5 and 38 m from the cooling pad and the temperature difference between theses two locations was 7.5 degrees C and 12 degrees C at ventilation rates of I and 0.5 ACM, respectively, during extreme hours of the day (from 1230 to 1500 h). The temperature difference increased as the solar radiation increased for both ventilation rates. The solar radiation effect oil temperature rise was more severe for the 0.5-ACM ventilation rate. Results showed that the daytime average of cooling water consumption with a ventilation rate of 0.5 ACM was 8.4 L/m(2) of floor area. Whereas, with a ventilation rate of I ACM, the average was 14 L/m(2) of floor area. A simple model for predicting the rate of water consumption by the evaporative cooling system was proposed. The model suggested that the daytime average of cooling water consumption with ventilation rates Of 0.5 and I ACM were 7.9 and 16.3 L/m(2) of floor area, respectively. The average electrical energy consumed from 0700 to 2000 h with ventilation rates of 0.5 and I ACM were 48.2 and 99.6 Wh/m(2) I respectively.


英文关键词greenhouse evaporative cooling ventilation rate fan ventilation pad shade electrical energy water consumption arid climate
类型Article
语种英语
国家Saudi Arabia
收录类别SCI-E
WOS记录号WOS:000245728800012
WOS关键词TEMPERATURE ; CROP
WOS类目Agricultural Engineering
WOS研究方向Agriculture
来源机构King Saud University
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/153475
作者单位(1)King Saud Univ, Coll Food & Agr Sci, Dept Agr Engn, Riyadh 11451, Saudi Arabia
推荐引用方式
GB/T 7714
Al-Helal, I. A.. Effects of ventilation rate on the environment of a fan-pad evaporatively cooled, shaded greenhouse in extreme arid climates[J]. King Saud University,2007,23(2):221-230.
APA Al-Helal, I. A..(2007).Effects of ventilation rate on the environment of a fan-pad evaporatively cooled, shaded greenhouse in extreme arid climates.APPLIED ENGINEERING IN AGRICULTURE,23(2),221-230.
MLA Al-Helal, I. A.."Effects of ventilation rate on the environment of a fan-pad evaporatively cooled, shaded greenhouse in extreme arid climates".APPLIED ENGINEERING IN AGRICULTURE 23.2(2007):221-230.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Al-Helal, I. A.]的文章
百度学术
百度学术中相似的文章
[Al-Helal, I. A.]的文章
必应学术
必应学术中相似的文章
[Al-Helal, I. A.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。