Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1002/bmc.589 |
Quantification of zolpidem in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry | |
Bhatt, Jignesh; Jangid, Arvind; Shetty, Raghavendra; Shah, Bhavin; Kambli, Sandeep; Subbaiah, Gunta; Singh, Sadhana | |
通讯作者 | Bhatt, Jignesh |
来源期刊 | BIOMEDICAL CHROMATOGRAPHY
![]() |
ISSN | 0269-3879 |
EISSN | 1099-0801 |
出版年 | 2006 |
卷号 | 20期号:8页码:736-742 |
英文摘要 | A simple and robust method for quantification of zolpidem in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI MS/MS). Es-citalopram was used as an internal standard. Zolpidem and internal standard in plasma sample were extracted using solid-phase extraction cartridges (Oasis HLB, 1 cm(3)/30 mg). The samples were injected into a C-8 reversed-phase column and the mobile phase used was acetonitrile-ammonium acetate (pH 4.6; 10 mM) (80:20, v/v) at a flow rate of 0.7 mL/min. Using MS/MS in the selected reaction-monitoring (SRM) mode, zolpidem and Es-citalopram were detected without any interference from human plasma matrix. Zolpidem produced a protonated precursor ion ([M+H](+)) at m/z 308.1 and a corresponding product ion at m/z 235.1. The internal standard produced a protonated precursor ion ([M+H](+)) at m/z 325.1 and a corresponding product ion at m/z 262.1. Detection of zolpidem in human plasma by the LC-ESI MS/MS method was accurate and precise with a quantification limit of 2.5 ng/mL. The proposed method was validated in the linear range 2.5-300 ng/mL. Reproducibility, recovery and stability of the method were evaluated. The method has been successfully applied to bioequivalence studies of zolpidem. Copyright (c) 2005 John Wiley & Sons, Ltd. |
英文关键词 | zolpidem bioequivalence studies LC-ESI MS/MS |
类型 | Article |
语种 | 英语 |
国家 | India |
收录类别 | SCI-E |
WOS记录号 | WOS:000239541300008 |
WOS关键词 | NITROGEN-PHOSPHORUS DETECTION ; GAS-CHROMATOGRAPHY ; VOLUNTARY INTOXICATION ; FLUORESCENCE DETECTION ; ZOPICLONE ; ALPIDEM ; SERUM |
WOS类目 | Biochemical Research Methods ; Biochemistry & Molecular Biology ; Chemistry, Analytical ; Pharmacology & Pharmacy |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry ; Pharmacology & Pharmacy |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/150943 |
作者单位 | (1)Torrent Pharmaceut Ltd, Torrent Res Ctr, Gandhinagar 382428, Gujarat, India;(2)Mohanlal Sukhadia Univ, Dept Chem, BNPG Coll, Udaipur, Rajasthan, India |
推荐引用方式 GB/T 7714 | Bhatt, Jignesh,Jangid, Arvind,Shetty, Raghavendra,et al. Quantification of zolpidem in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry[J],2006,20(8):736-742. |
APA | Bhatt, Jignesh.,Jangid, Arvind.,Shetty, Raghavendra.,Shah, Bhavin.,Kambli, Sandeep.,...&Singh, Sadhana.(2006).Quantification of zolpidem in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry.BIOMEDICAL CHROMATOGRAPHY,20(8),736-742. |
MLA | Bhatt, Jignesh,et al."Quantification of zolpidem in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry".BIOMEDICAL CHROMATOGRAPHY 20.8(2006):736-742. |
条目包含的文件 | 条目无相关文件。 |