Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.solener.2004.05.021 |
Response of conventional and energy-saving buildings to design and human dependent factors | |
Filippin, C; Larsen, SF; Beascochea, A; Lesino, G | |
通讯作者 | Filippin, C |
来源期刊 | SOLAR ENERGY
![]() |
ISSN | 0038-092X |
出版年 | 2005 |
卷号 | 78期号:3页码:455-470 |
英文摘要 | During the year 2000, energy-efficient buildings for low-income students at La Pampa University were designed and constructed. Buildings are located at the centre of La Pampa province, in a temperate semi-arid region of central Argentina Socio-economic, educational and environmental reasons have driven the design. Energy conservation devices, passive solar heating, natural ventilation and solar protection were the main strategies. The resulting design comprises two blocks of apartments with a useful floor area of 700 m(2) and main spaces. Two bedrooms, a dining room and essential services make up each apartment. Solar windows are provided for all main spaces. Northern shading devices and metallic pergolas protect all windows in summer. Once the building was finished, a monitoring plan started on December 2000. This paper shows the results of the thermal and energy behavior of apartments. The evolution of internal temperature was different in each apartment. The consumption of natural gas varied among dwellers, but the volume consumed was lower than that of conventional dwellings. Without extra building cost dwellers live under good higrothermal conditions at 50% of the auxiliary energy consumed by conventional dwellings. (c) 2004 Elsevier Ltd. All rights reserved. |
英文关键词 | energy-saving building passive solar design night ventilation energy saving low-income students comfort |
类型 | Article |
语种 | 英语 |
收录类别 | SCI-E |
WOS记录号 | WOS:000227686800010 |
WOS关键词 | ARGENTINA |
WOS类目 | Energy & Fuels |
WOS研究方向 | Energy & Fuels |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/150406 |
推荐引用方式 GB/T 7714 | Filippin, C,Larsen, SF,Beascochea, A,et al. Response of conventional and energy-saving buildings to design and human dependent factors[J],2005,78(3):455-470. |
APA | Filippin, C,Larsen, SF,Beascochea, A,&Lesino, G.(2005).Response of conventional and energy-saving buildings to design and human dependent factors.SOLAR ENERGY,78(3),455-470. |
MLA | Filippin, C,et al."Response of conventional and energy-saving buildings to design and human dependent factors".SOLAR ENERGY 78.3(2005):455-470. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。