Extraction of 15 microcystins and nodularin using immunoaffinity columns | |
Aranda-Rodriguez, R; Kubwabo, C; Benoit, FM | |
通讯作者 | Aranda-Rodriguez, R |
来源期刊 | TOXICON
![]() |
ISSN | 0041-0101 |
出版年 | 2003 |
卷号 | 42期号:6页码:587-599 |
英文摘要 | Microcystins (MCYSTs) were isolated from surface water using reusable immunoaffinity columns. Individual MCYST were determined by high performance liquid chromatography equipped with a photo-diode array detector (HPLC-PDA, 200-300 nm). Subsequent analysis of the samples by liquid chromatography-electrospray ionization mass spectrometry (LC-ESMS) provided molecular weight information, which was used to tentatively identify individual MCYST variants for which standards were not available. Results obtained using immunoaffinity columns (IAC)-HPLC-PDA were compared to those obtained using solid phase extraction (SPE) Oasis(R) HLB-HPLC-PDA. This is the first report of the extraction of 15 microcystins and nodularin using immunoaffinity columns. Whereas previous reports demonstrates the use of IAC for four microcystins, we found that IAC selectively extracted the following microcystins: MCYST-RR, [D-Asp(3)]MCYST-RR, MCYST-YR, MCYST-LR, 3 MCYST-LR variants, MCYST-AR, MCYST-FR, MCYST-WR, MCYST-LA, MCYST-LA variant, the less polar microcystins such as MCYST-LF, MCYST-LW and nodularin. The IAC extracts were free of interferences which enabled better detection and identification of MCYSTs. Based on the amount loaded to the cartridges, the method detection limit was 10-14 ng when using IAC and 25 ng for SPE of each MCYST-RR, MCYST-YR and MCYST-LR. Reproducibilities expressed as relative standard deviation were 6-10% for SPE and 4-17% for IAC. Crown Copyright (C) 2003 Published by Elsevier Ltd. All rights reserved. |
英文关键词 | microcystins nodularin liquid chromatography-electrospray ionization mass spectrometry solid-phase extraction immunoaffinity columns Oasis (R) HLB |
类型 | Article |
语种 | 英语 |
国家 | Canada |
收录类别 | SCI-E |
WOS记录号 | WOS:000186673300003 |
WOS关键词 | PERFORMANCE LIQUID-CHROMATOGRAPHY ; PHOSPHATASE INHIBITION ASSAY ; LINKED-IMMUNOSORBENT-ASSAY ; BLUE-GREEN-ALGAE ; HEPTAPEPTIDE MICROCYSTINS ; CYANOBACTERIAL TOXINS ; MONOCLONAL-ANTIBODIES ; MASS-SPECTROMETRY ; LAKE WATER ; CLEANUP |
WOS类目 | Pharmacology & Pharmacy ; Toxicology |
WOS研究方向 | Pharmacology & Pharmacy ; Toxicology |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/145933 |
作者单位 | (1)Hlth Canada, Hlth Environm & Consumer Safety Branch, Safe Environm Programme, Div Chem Res, Ottawa, ON K1A 0L2, Canada |
推荐引用方式 GB/T 7714 | Aranda-Rodriguez, R,Kubwabo, C,Benoit, FM. Extraction of 15 microcystins and nodularin using immunoaffinity columns[J],2003,42(6):587-599. |
APA | Aranda-Rodriguez, R,Kubwabo, C,&Benoit, FM.(2003).Extraction of 15 microcystins and nodularin using immunoaffinity columns.TOXICON,42(6),587-599. |
MLA | Aranda-Rodriguez, R,et al."Extraction of 15 microcystins and nodularin using immunoaffinity columns".TOXICON 42.6(2003):587-599. |