Arid
DOI10.1016/S0731-7085(01)00541-6
The investigation and the use of high flow column-switching LC/MS/MS as a high-throughput approach for direct plasma sample analysis of single and multiple components in pharmacokinetic studies
Zeng, H; Wu, JT; Unger, SE
通讯作者Zeng, H
来源期刊JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
ISSN0731-7085
出版年2002
卷号27期号:6页码:967-982
英文摘要

Recently direct plasma injection LC/MS/MS technique has been increasingly used in pharmaceutical research and development due to the demand for higher throughput of sample analyses. In this work, two on-line extraction methods including high flow LC/MS/MS and high flow column switching LC/MS/MS were investigated. The evaluations were conducted and focused on their performances with respect to peak responses, separation efficiency, and signal to-noise ratio in a multiple-component LC/MS/MS assay. Two HPLC pumps were used-with one for high flow delivery and one for gradient elution. A CTC autosampler was used to inject plasma samples. High flow LC was achieved by the use of 4 ml/min flow rate on a 1 x 50 mm Waters Oasis column. A 2 x 100 mm YMC column was coupled via a column-switching valve. The extracted analytes were analyzed in multiple-reaction-monitoring (MRM) mode using a triple quadrupole MS/MS. As a rapid and simple procedure, vortex-mixing plasma and internal standard directly in sample vials completed sample preparation. The high flow column switching method (two-column system) provided sharper peak shape than the conventional high flow method. This effect increased analyte signal-to-noise ratio and sensitivity. Narrower peak width resulted in much better separation efficiency, which was required for multiple compound (N-in-1) analysis. A 2 mm I.D. column resulted in better peak shape and resolution than using a smaller I.D. column. The selected method achieved acceptable recoveries for most of the compounds tested, and it was successfully applied to a 10-in-1 pharmacokinetic (PK) study. The results showed that the dynamic range, lower limit of quantitation, assay accuracy and precision were acceptable for all compounds. Rapid sample preparation eliminated labor intensive and time consuming processes and improved productivity. This high through-put on-line extraction high flow column switching method has been proven particularly useful for multiple component analysis in PK studies. (C) 2002 Dupont Pharmaceuticals. Published by Elsevier Science B.V. All rights reserved.


英文关键词bioanalysis high flow column switching direct plasma injection resolution extraction efficiency pharmacokinetics
类型Article
语种英语
国家USA
收录类别SCI-E
WOS记录号WOS:000174352200013
WOS关键词SOLID-PHASE EXTRACTION ; TANDEM MASS-SPECTROMETRY ; PERFORMANCE LIQUID-CHROMATOGRAPHY ; DIRECT-INJECTION ; 96-WELL FORMAT ; QUANTITATION ; BIOANALYSIS ; SYSTEM ; CANDIDATES
WOS类目Chemistry, Analytical ; Pharmacology & Pharmacy
WOS研究方向Chemistry ; Pharmacology & Pharmacy
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/143222
作者单位(1)Dupont Pharmaceut Co, Drug Metab & Pharmacokinet, Newark, DE 19714 USA
推荐引用方式
GB/T 7714
Zeng, H,Wu, JT,Unger, SE. The investigation and the use of high flow column-switching LC/MS/MS as a high-throughput approach for direct plasma sample analysis of single and multiple components in pharmacokinetic studies[J],2002,27(6):967-982.
APA Zeng, H,Wu, JT,&Unger, SE.(2002).The investigation and the use of high flow column-switching LC/MS/MS as a high-throughput approach for direct plasma sample analysis of single and multiple components in pharmacokinetic studies.JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS,27(6),967-982.
MLA Zeng, H,et al."The investigation and the use of high flow column-switching LC/MS/MS as a high-throughput approach for direct plasma sample analysis of single and multiple components in pharmacokinetic studies".JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS 27.6(2002):967-982.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zeng, H]的文章
[Wu, JT]的文章
[Unger, SE]的文章
百度学术
百度学术中相似的文章
[Zeng, H]的文章
[Wu, JT]的文章
[Unger, SE]的文章
必应学术
必应学术中相似的文章
[Zeng, H]的文章
[Wu, JT]的文章
[Unger, SE]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。