Arid
DOI10.1016/S0731-7085(00)00398-8
Determination of pibutidine metabolites in human plasma by LC-MS/MS
Kato, K; Jingu, S; Ogawa, N; Higuchi, S
通讯作者Kato, K
来源期刊JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
ISSN0731-7085
出版年2000
卷号24期号:2页码:237-249
英文摘要

A novel metabolite-screening procedure for pibutidine. an H-2-receptor antagonist, which uses high-performance liquid chromatography/tandem mass spectrometry (LC-MS/MS), demonstrated the presence of pibutidine and its four metabolites in plasma from volunteers who received a single dose of pibutidine hydrochloride. In order to quantitatively examine the metabolism of pibutidine, an assay based on LC-MS/MS was subsequently developed for the simultaneous determination of its metabolites in human plasma. Target analytes consisted of M-5, M-7 and M-8, which were prominently detected by the screening procedure, and M-9, which has pharmacological activity as an H-2-receptor antagonist. Metabolites and their deuterated internal standards were extracted from human plasma using an Oasis HLB extraction cartridge, and chromatographed on a Monitor C18M column. No isotope effects on chromatographic retention time were observed for any deuterated compounds, which were ionized using an electrospray ionization (ESI)- interface and detected by MS/MS in the selected reaction-monitoring (SRM) mode simultaneously with the corresponding metabolites. The assay was validated over the concentration range of 0.1 to 25.6 ng ml(-1) and used to determine the plasma levels of metabolites in volunteers following oral administration of a 20-mg dose of pibutidine hydrochloride. (C) 2000 Elsevier Science B.V. All rights reserved.


英文关键词pibutidine metabolism human plasma LC-MS/MS electrospray ionization isotope effect
类型Article
语种英语
国家Japan
收录类别SCI-E
WOS记录号WOS:000165720000008
WOS关键词MASS-SPECTROMETRY ; ANTAGONIST ; RECEPTOR
WOS类目Chemistry, Analytical ; Pharmacology & Pharmacy
WOS研究方向Chemistry ; Pharmacology & Pharmacy
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/139460
作者单位(1)Taisho Pharmaceut Co Ltd, Pharmaceut Res Labs, Drug Metab Lab, Omiya, Saitama 3308530, Japan
推荐引用方式
GB/T 7714
Kato, K,Jingu, S,Ogawa, N,et al. Determination of pibutidine metabolites in human plasma by LC-MS/MS[J],2000,24(2):237-249.
APA Kato, K,Jingu, S,Ogawa, N,&Higuchi, S.(2000).Determination of pibutidine metabolites in human plasma by LC-MS/MS.JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS,24(2),237-249.
MLA Kato, K,et al."Determination of pibutidine metabolites in human plasma by LC-MS/MS".JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS 24.2(2000):237-249.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Kato, K]的文章
[Jingu, S]的文章
[Ogawa, N]的文章
百度学术
百度学术中相似的文章
[Kato, K]的文章
[Jingu, S]的文章
[Ogawa, N]的文章
必应学术
必应学术中相似的文章
[Kato, K]的文章
[Jingu, S]的文章
[Ogawa, N]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。