Arid
DOI10.1016/S0021-9673(99)00535-X
Comparison of turbulent-flow chromatography with automated solid-phase extraction in 96-well plates and liquid-liquid extraction used as plasma sample preparation techniques for liquid chromatography-tandem mass spectrometry
Zimmer, D; Pickard, V; Czembor, W; Muller, C
通讯作者Zimmer, D
来源期刊JOURNAL OF CHROMATOGRAPHY A
ISSN0021-9673
出版年1999
卷号854期号:1-2页码:23-35
英文摘要

Turbulent flow chromatography (TFC) combined with the high selectivity and sensitivity of tandem mass spectrometry (MS-MS) is a new technique for the fast direct analysis of drugs from crude plasma. TFC in the 96-well plate format reduces significantly the time required for sample clean-up in the laboratory. For example, for 100 samples the workload for a technician is reduced from about 8 h by a manual liquid-liquid extraction (LLE) assay to about 1 h in the case of TFC. Sample clean-up and analysis are performed on-line on the same column. Similar chromatographic performance and validation results were achieved using HTLC Turbo-C-18 columns (Cohesive Technologies) and Oasis HLB extraction columns (Waters). One 96-well plate with 96 plasma samples is analyzed within 5.25 h, corresponding to 3.3 min per sample. Compared to this LLE and analysis of 96 samples takes about 16 h. Two structurally different and highly protein bound compounds, drug A and drug B, were analyzed under identical TFC conditions and the assays were fully validated for the application to toxicokinetics studies (compliant with Good Laboratory Practices - GLP). The limit of quantitation was 1.00 mu g/l and the linear working range covered three orders of magnitude for both drugs. In the case of drug A the quality of analysis by TFC was similar to the reference LLE assay and slightly better than automated solid-phase extraction in 96-well plates. The accuracy was -3.1 to 6.7% and the precision was 3.1 to 6.8% in the case of drug A determined for dog plasma by TFC-MS-MS. For drug B the accuracy was -3.7 to 3.5% and the precision was 1.6 to 5.4% for rat plasma, which is even slightly better than what was achieved with the validated protein precipitation assay. (C) 1999 Elsevier Science B.V. All rights reserved.


英文关键词turbulent flow chromatography sample preparation validation pharmaceutical analysis
类型Article ; Proceedings Paper
语种英语
国家Germany
收录类别CPCI-S ; SCI-E
WOS记录号WOS:000082445200004
WOS类目Biochemical Research Methods ; Chemistry, Analytical
WOS研究方向Biochemistry & Molecular Biology ; Chemistry
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/137636
作者单位(1)Bayer AG, Preclin Pharmacokinet, D-42096 Wuppertal, Germany
推荐引用方式
GB/T 7714
Zimmer, D,Pickard, V,Czembor, W,et al. Comparison of turbulent-flow chromatography with automated solid-phase extraction in 96-well plates and liquid-liquid extraction used as plasma sample preparation techniques for liquid chromatography-tandem mass spectrometry[J],1999,854(1-2):23-35.
APA Zimmer, D,Pickard, V,Czembor, W,&Muller, C.(1999).Comparison of turbulent-flow chromatography with automated solid-phase extraction in 96-well plates and liquid-liquid extraction used as plasma sample preparation techniques for liquid chromatography-tandem mass spectrometry.JOURNAL OF CHROMATOGRAPHY A,854(1-2),23-35.
MLA Zimmer, D,et al."Comparison of turbulent-flow chromatography with automated solid-phase extraction in 96-well plates and liquid-liquid extraction used as plasma sample preparation techniques for liquid chromatography-tandem mass spectrometry".JOURNAL OF CHROMATOGRAPHY A 854.1-2(1999):23-35.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zimmer, D]的文章
[Pickard, V]的文章
[Czembor, W]的文章
百度学术
百度学术中相似的文章
[Zimmer, D]的文章
[Pickard, V]的文章
[Czembor, W]的文章
必应学术
必应学术中相似的文章
[Zimmer, D]的文章
[Pickard, V]的文章
[Czembor, W]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。