Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/S0731-7085(98)00075-2 |
Comparison of the properties of polymeric and C8 based materials for solid phase extraction | |
Martin, P; Wilson, ID | |
通讯作者 | Martin, P |
来源期刊 | JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS
![]() |
ISSN | 0731-7085 |
出版年 | 1998 |
卷号 | 17期号:6-7页码:1093-1100 |
英文摘要 | The extraction properties of two polymeric solid phase extraction materials, styryldivinyl benzene (SDB) and ’Oasis’(TM) have been compared with those of a base deactivated C8 bonded silica gel using a range of acidic and basic test analytes. In the case of the two polymer phases good extraction of all the test compounds from aqueous buffer was obtained over the pH range 2-10. On the C8 material, efficient extraction of the most polar acidic analyte, anisic acid, was only obtained between pH 2 and 6. The use of methanol water mixtures? or methanol-water mixtures modified with either trifluoroacetic acid (TFA) or triethylamine (TEA) as eluents was investigated for the recovery of the analytes following extraction. The use of TFA or TEA as ionic modifiers strongly influenced the efficiency of the elution step. The effect of a plasma matrix on extraction efficiency was also investigated, with the result depending upon the analyte. An approach to assessing the performance of the three phases has been developed based on the percentages of methanol in the eluent resulting in the recovery of 50% of the analyte, and in determining the difference between eluents giving recoveries of 10 and 90%. (C) 1998 Elsevier Science B.V. All rights reserved. |
英文关键词 | styryldivinylbenzene ’OASIS’ C8 bonded silica anisic acid propranolol ICI 128,436 |
类型 | Article |
语种 | 英语 |
国家 | England |
收录类别 | SCI-E |
WOS记录号 | WOS:000077966000018 |
WOS关键词 | BONDED SILICA |
WOS类目 | Chemistry, Analytical ; Pharmacology & Pharmacy |
WOS研究方向 | Chemistry ; Pharmacology & Pharmacy |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/136249 |
作者单位 | (1)Zeneca Pharmaceut, Dept Safety Med, Macclesfield SK10 4TG, Cheshire, England |
推荐引用方式 GB/T 7714 | Martin, P,Wilson, ID. Comparison of the properties of polymeric and C8 based materials for solid phase extraction[J],1998,17(6-7):1093-1100. |
APA | Martin, P,&Wilson, ID.(1998).Comparison of the properties of polymeric and C8 based materials for solid phase extraction.JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS,17(6-7),1093-1100. |
MLA | Martin, P,et al."Comparison of the properties of polymeric and C8 based materials for solid phase extraction".JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS 17.6-7(1998):1093-1100. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Martin, P]的文章 |
[Wilson, ID]的文章 |
百度学术 |
百度学术中相似的文章 |
[Martin, P]的文章 |
[Wilson, ID]的文章 |
必应学术 |
必应学术中相似的文章 |
[Martin, P]的文章 |
[Wilson, ID]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。