Arid
DOI10.1016/S0021-9673(98)00393-8
Comparison of simplified methods for pesticide residue analysis - Use of large-volume injection in capillary gas chromatography
Lopez, FJ; Beltran, J; Forcada, M; Hernandez, F
通讯作者Lopez, FJ
来源期刊JOURNAL OF CHROMATOGRAPHY A
ISSN0021-9673
出版年1998
卷号823期号:1-2页码:25-33
英文摘要

The combination of manual and automated extraction procedures using low sample volumes (5-50 ml) with large-volume oncolumn injection (LVI) (200 mu l) in capillary gas chromatography with flame photometric detection (GC-FPD) has allowed the determination of 16 organophosphorus pesticides in clean water samples at the low ng l(-1) level with an important simplification in the sample preparation step. A simple and fast offline liquid-liquid microextraction procedure (2-5 ml water/1 ml methyl tert.-butyl ether) has been applied to spiked groundwater samples (containing 0.5 ng of each pesticide) with good recoveries lover 80%) and precision (better than 10%), giving detection limits between 5 and 100 ng l(-1) using 200 mu l injections in the GC-FPD system. The application of an inline automated Liquid-Liquid microextraction-LVI-GC procedure (2 ml water/2 ml methyl tert.-butyl ether: injection of 200 mu l in GC-FPD) using the autosampler ASPEC XL led to lower recoveries (>50%) as a result of the low efficiency for mixing organic and aqueous phases, although with very satisfactory coefficients of variation (lower than 78) and detection Limits between 20 and 200 ng l(-1). Manual and automated solid-phase extraction procedures using the well known C-18 cartridges and the new Oasis HLB have been applied to groundwater samples (5-50 ml) spiked with 1 ng of each pesticide. Results obtained for both the manual and the automated procedures were satisfactory (recoveries over 80%) and the limits of detection for 50 ml sample volume ranged from 1 to 6 ng l(-1). (C) 1998 Elsevier Science B.V. All rights reserved.


英文关键词extraction methods water analysis environmental analysis pesticides organophosphorus compounds large-volume injection injection methods
类型Article ; Proceedings Paper
语种英语
国家Spain
收录类别CPCI-S ; SCI-E
WOS记录号WOS:000076610900005
WOS关键词SOLID-PHASE EXTRACTION ; ON-COLUMN INJECTION ; ATOMIC-EMISSION DETECTION ; AQUEOUS SAMPLES ; WATER ; SOLVENT
WOS类目Biochemical Research Methods ; Chemistry, Analytical
WOS研究方向Biochemistry & Molecular Biology ; Chemistry
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/136106
作者单位(1)Univ Jaume 1, Expt Sci Dept, Castellon de La Plana 12080, Spain
推荐引用方式
GB/T 7714
Lopez, FJ,Beltran, J,Forcada, M,et al. Comparison of simplified methods for pesticide residue analysis - Use of large-volume injection in capillary gas chromatography[J],1998,823(1-2):25-33.
APA Lopez, FJ,Beltran, J,Forcada, M,&Hernandez, F.(1998).Comparison of simplified methods for pesticide residue analysis - Use of large-volume injection in capillary gas chromatography.JOURNAL OF CHROMATOGRAPHY A,823(1-2),25-33.
MLA Lopez, FJ,et al."Comparison of simplified methods for pesticide residue analysis - Use of large-volume injection in capillary gas chromatography".JOURNAL OF CHROMATOGRAPHY A 823.1-2(1998):25-33.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Lopez, FJ]的文章
[Beltran, J]的文章
[Forcada, M]的文章
百度学术
百度学术中相似的文章
[Lopez, FJ]的文章
[Beltran, J]的文章
[Forcada, M]的文章
必应学术
必应学术中相似的文章
[Lopez, FJ]的文章
[Beltran, J]的文章
[Forcada, M]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。