Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1029/94JC00920 |
CALIBRATION OF THE TOPEX ALTIMETER USING A GPS BUOY | |
BORN, GH; PARKE, ME; AXELRAD, P; GOLD, KL; JOHNSON, J; KEY, KW; KUBITSCHEK, DG; CHRISTENSEN, EJ | |
通讯作者 | BORN, GH |
来源期刊 | JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS
![]() |
ISSN | 2169-9275 |
EISSN | 2169-9291 |
出版年 | 1994 |
卷号 | 99期号:C12页码:24517-24526 |
英文摘要 | The use of a spar buoy equipped with a Global Positioning System (GPS) antenna to calibrate the height measurement of the TOPEX radar altimeter is described. In order to determine the height of the GPS antenna phase center above the ocean surface, the buoy was also equipped with instrumentation to measure the instantaneous location of the waterline, and tilt of the buoy from vertical. The experiment was conducted off the California coast near the Texaco offshore oil platform, Harvest, during cycle 34 of the TOPEX/POSEIDON observational period. GPS solutions were computed for the buoy position using two different software packages, K&RS and GIPSY-OASIS II. These solutions were combined with estimates of the waterline location on the buoy to yield the height of the ocean surface. The ocean surface height in an absolute coordinate system combined with knowledge of the spacecraft height from tracking data provides a computed altimeter range measurement. By comparing this computed value to the actual altimeter measurement, the altimeter bias can be calibrated. The altimeter height bias obtained with the buoy using K&RS was -14.6+/-4 cm, while with GIPSY-OASIS II it was -13.1+/-4 cm. These are 0.1 cm and 1.6 cm different from the -14.7+/-4 cm result obtained for this overflight with the tide gauge instruments located on Platform Harvest. |
类型 | Article |
语种 | 英语 |
国家 | USA |
收录类别 | SCI-E |
WOS记录号 | WOS:A1994PX77300009 |
WOS关键词 | GLOBAL POSITIONING SYSTEM |
WOS类目 | Oceanography |
WOS研究方向 | Oceanography |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/130321 |
作者单位 | (1)CALTECH, JET PROP LAB, PASADENA, CA USA |
推荐引用方式 GB/T 7714 | BORN, GH,PARKE, ME,AXELRAD, P,et al. CALIBRATION OF THE TOPEX ALTIMETER USING A GPS BUOY[J],1994,99(C12):24517-24526. |
APA | BORN, GH.,PARKE, ME.,AXELRAD, P.,GOLD, KL.,JOHNSON, J.,...&CHRISTENSEN, EJ.(1994).CALIBRATION OF THE TOPEX ALTIMETER USING A GPS BUOY.JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS,99(C12),24517-24526. |
MLA | BORN, GH,et al."CALIBRATION OF THE TOPEX ALTIMETER USING A GPS BUOY".JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS 99.C12(1994):24517-24526. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。